Tag Archives: Zirconium fasteners for HCl corrosion

Q: Can I use zirconium bolts in boiling HCl. Concentration would be about 5%? A: Yes, zirconium fasteners work well in hydrochloric acid but may be a bit overkill at that relatively low concentration but depends on the temperature and other media it may be exposed to. Zirconium screws do … Continue reading

Posted in Application, Corrosion Resistance, FAQs, Specialty Metal Fasteners, Technical Questions | Tagged , , , , , | Leave a comment

Q: I have a process that utilizes about 10% hydrochloric acid with trace amounts of other chemicals. I tried zirconium bolts because they are known for HCl but we’re burning through them like crazy and I can’t figure out why they are corroding. Any ideas and what other material may … Continue reading

Posted in Application, Corrosion Resistance, FAQs, Specialty Metal Fasteners, Technical Questions | Tagged , , , , , , , , , , , , | Leave a comment

Q: We have on application that utilizes an HCl tank and are currently using hastelloy C276 bolts but they are not sufficient. Should we try tantalum fasteners or anther material like PEEK? The bolts are for a flanged valves connections  concentration is 36%, temperature 45ºC. A: Though the HCl is … Continue reading

Posted in Application, Corrosion Resistance, Engineered Polymer Fasteners, FAQs, Material, Specialty Metal Fasteners, Technical Questions | Tagged , , , , , , , , , , , , , , , , , , , , , | Leave a comment