Q: What is the difference between Inconel 718 standard and NACE 718? A: NACE stands for the National Association of Corrosion Engineers. This group puts forth standards for corrosion resistant materials and when the NACE certification is asked for, the user is typically asking for NACE MR0175. Inconel 718 that meets … Continue reading

Posted in Application, Corrosion Resistance, FAQs, High Strength, High Temperature Resistance, Material, Specialty Metal Fasteners, Technical Questions | Tagged , , , , , , , , , , , | Leave a comment

Q: We are currently using A286 bolts per ASTM 453 at 1200F and are having some issues with durability as the tensile strength we originally calculated necessary was 130ksi but seems like we need higher strengths. Any ideas? A: In this type of environment you should consider A-286 in the … Continue reading