Tag Archives: ferric chloride

Inline image 1Q: I was planning on using Hastelloy C276 in hot sulfuric acid. It would be approximately 50% concentration around 100F +/- 10 degrees. Will this be okay? I’m just concerned because I read that it cannot handle strong oxidizing environments and I’ll be using it in an application where its … Continue reading

Posted in Application, Corrosion Resistance, FAQs, Material, Specialty Metal Fasteners, Technical Questions | Tagged , , , , , , , , , , , , | Leave a comment

Q: I have a waste water purifying situation where I’m using chlorine to treat the water. In addition to the acidic solution produced the fastener will also experience high loads, so I’m also concerned with stress corrosion cracking. Currently Super Duplex 2507 is not doing the job. Any recommendations on … Continue reading

Posted in Application, Corrosion Resistance, FAQs, High Strength, Specialty Metal Fasteners, Technical Questions | Tagged , , , , , , , , | Leave a comment